Dorchester DR-CC compact condensing water heater
Fully automatic, simple to operate condensing direct fired water heater for domestic hot water.
9 models available with continuous outputs (@44°C ∆T) of 228, 233, 374, 461, 465, 602, 608 & 614 l/h.
Product information
- Low power outputs 11-29kW and storage capacities of 162-384 litres.
- Compact, standalone water heating unit for safe and clean domestic hot water generation.
- No clearances required at the rear and minimal clearances at top and sides allow easy siting in any plant room.
- Reduces energy use and running costs by maximising condensing water heater performance.
- Meets the strict standards for efficiencies and NOx emissions (under 37 mg/kWh) in new buildings.
- Load profiles of XL or XXL and an A rating ensure all models in the range are fully compliant with the ErP (Energy-related Products Directive) regulations.
- Closely matches hot water demand, reducing wastage of energy.
- Electronic Anode fitted as standard to protect against corrosion.
- No top-to-bottom re-circulation kit required due to the heat exchanger coil positioned in the centre of the unit for even heat distribution and reduced likelihood of stratification.
- Down firing pre-mix modulating burner reduces the risk of scale build up impacting on the heat transfer.
- Natural gas and LPG water heater options.
- All components accessible under front cover for ease of service and maintenance.
- Flexible flue options (see optional extras tab and brochure for details).
- Full project assistance available from our dedicated hot water expert to help with hot water sizing and selection of equipment to match the application.
- Extensive back up and support from our team of experienced engineers across the UK.
- Long-term commitment to spare parts.
- BIM objects available to assist in design and management
- Available for next day delivery (dependent on stock availability, charges apply, order cut-off 12pm).
Technical data
Units | DR-CC 12-160 | |
---|---|---|
Water | ||
Continuous output with 44°C ΔT | l/h | 228 |
1st hour output with 44°C ΔT | l | 360 |
Continuous output with 50°C ΔT | l/h | 201 |
1st hour output with 50°C ΔT | l | 310 |
Continuous output with 56°C ΔT | l/h | 180 |
1st hour output with 56°C ΔT | l | 270 |
Storage capacity | litres | 162 |
Maximum working pressure | bar | 8 |
ErP load profile | - | XL |
Energy | ||
Building Regulations thermal efficiency gross | % | 96 |
ErP efficiency rating | - | A |
Heating-up time, ΔT = 44°C | min. | 27 |
Heating-up time, ΔT = 50°C | min. | 31 |
Heating-up time, ΔT = 56°C | min. | 34 |
Standby losses | kW/24h | 2.16 |
Nat Gas | ||
Input, gross – maximum | kW | 12.1 |
Input, net - maximum | kW | 10.9 |
Output – maximum | kW | 11.7 |
Gas inlet pressure – nominal | mbar | 20 |
Gas flow rate – maximum @1013.25 mbar and 15°C | m3/h | 1.2 |
LPG | ||
Input, gross – maximum | kW | 11.8 |
Output – maximum | kW | 11.4 |
Gas inlet pressure – nominal | mbar | 37 |
Gas flow rate – maximum@1013.25 mbar and 15°C | kg/h | 0.8 |
Flue | ||
Flue gas temperature – maximum | °C | 42 |
NOx emission, dry air free* | mg/kWh | 22 |
Pressure at the flue outlet only (B23)** | Pa | 33 |
Electrical | ||
Start current–maximum (maximum power) | A (W) | 25 |
Run current–maximum (maximum power) | A (W) | 85 |
Electrical supply | Vac | 230V 50Hz |
Voltage tolerance | % of Vac | -15% +10% |
Misc. | ||
Noise level | dB(A) | 41 |
Number of anodes | - | 1 |
Weight when empty | kg | 95 |
Approximate shipping weight | kg | 114 |
Maximum floor load/ weight filled with water | kg | 255 |
*European Class 6. Max (at part load) | ||
**with zero pressure at air inlet |
Downloads
Dorchester DR-CC water heater product brochureProduct brochures 2831 kb |
Download | |
Dorchester DR-CC installation manualInstallers guides 7420 kb |
Download | |
Dorchester DR-CC water heater hydraulic schemesHydraulic schematics 126 kb |
Download | |
Dorchester DR-CC 160 front CADCAD 138 kb |
Download | |
Dorchester DR-CC 160 side CADCAD 100 kb |
Download | |
Dorchester DR-CC 160 top CADCAD 136 kb |
Download | |
Dorchester DR-CC 200 front CADCAD 140 kb |
Download | |
Dorchester DR-CC 200 side CADCAD 102 kb |
Download | |
Dorchester DR-CC 200 top CADCAD 135 kb |
Download | |
Dorchester DR-CC 245 front CADCAD 164 kb |
Download | |
Dorchester DR-CC 245 side CADCAD 122 kb |
Download |
Ideal uses/applications
- New build projects.
- Small to medium sized commercial and public buildings including schools, hospitals and hotels.
- Smaller premises including school kitchens, hair salons, bed & breakfasts.
Optional extras
- Unvented water supply kit - essential for any unvented application. Includes an expansion vessel sized for the water heater and local pipework only.
- Room Sealed Flue Systems:
- Concentric flue systems type C13–Horizontal termination.
- Concentric flue systems type C33–Vertical termination.
- Concentric flue systems type C43.
- Twin duct flue systems type C53–Vertical flue termination with Horizontal air inlet.
- Conventional Open Flue Systems:
- Open flue systems type B23–Vertical termination.
- Choose from a wide range of service contracts to help maintain optimum performance of your water heater.
- Book commissioning at the same time as placing your order for improved warranty terms.