Varmax floor standing boiler
Floor standing, high output condensing boiler with a stainless steel heat exchanger.
New larger models added November 2020 - The range consists of 10 single boilers with outputs (at 50/30°C) of 127, 148, 191, 238, 290, 338, 415, 478, 558, 637kW.
Product information
- Improved efficiency on split temperature systems due to high and low temperature return connections.
- Non-dependent on system flow allowing wide differential temperatures.
- Easier installation with no requirement for dedicated primary circuit and no minimum flow rates.
- Tolerant to a wide range of system water conditions with a corrosion resistant stainless steel heat exchanger.
- Long life backed up by a 5-year heat exchanger warranty.
- Well insulated for low standby losses.
- NOx emissions comply with ErP legislation lower than 56mg/kWh.
- Match heating system loads accurately with outputs up to 637kW from a single boiler and ability to cascade multiple boilers.
- Simplified flue system design as the flue gas non-return valve is built in to provide effective protection from re-circulation of flue gases through non-firing boilers.
- Built in boiler sequence controls capable of controlling up to 16 boiler modules, multiple heating circuits and a hot water circuit using the master/slave principle.
- Quick release access panels for ease of service and maintenance.
- BIM objects available to assist in design and management.
Technical data
Units | 120 | |
---|---|---|
Energy | ||
Building regulations Part L seasonal efficiency | % gross | 96.13 |
Boiler output - maximum 80/60°C, NG & LPG* | kW | 117 |
Boiler output - maximum 50/30°C, NG & LPG* | kW | 127 |
Boiler output - minimum 80/60°C, Nat Gas. | kW | 27.3 |
Boiler output - minimum 80/60°C, LPG | kW | 38 |
Boiler input (gross) - maximum, NG & LPG* | kW | 120 |
Boiler input (net) - maximum, NG & LPG* | kW | 108 |
Standby loss | W | 182 |
Water | ||
Water content | litres | 116 |
System design flow rate @ 30°C ΔT rise | l/s | 0.9 |
Water side pressure loss @ 30°C ΔT rise | mbar | 27 |
System design flow rate @ 20°C ΔT rise | l/s | 1.4 |
Water side pressure loss @ 20°C ΔT rise | mbar | 60 |
System design flow rate @ 11°C ΔT rise | l/s | 2.5 |
Water side pressure loss @ 11°C ΔT rise | mbar | 198 |
Minimum water pressure | barg | 1 |
Maximum water pressure | barg | 6 |
Minimum flow temperature setting | °C | 22 |
Maximum flow temperature setting | °C | 85 |
Gas | ||
Gas flow rate, NG (G20) - maximum | m³/hr | 12.7 |
Maximum gas inlet pressure, Nat Gas | mbar | 25 |
Nominal inlet pressure, Nat Gas | mbar | 20 |
Minimum gas inlet pressure, Nat Gas | mbar | 17 |
Gas flow rate, LPG (G31) - maximum | m³/hr | 4.9 |
Nominal inlet pressure, LPG | mbar | 37 |
Flue | ||
Maximum flue gas temperature @ 80/60°C Nat Gas | °C | 60.8 |
Pressure at boiler flue spigot @ 80/60°C Nat Gas B23P | Pa | 200 |
Maximum flue gas temperature @ 80/60°C LPG | °C | 60.3 |
Pressure at boiler flue spigot @ 80/60°C LPG B23P | Pa | 167 |
Dry NOx emission** | mg/kWh | 30 |
NOx Class | 6 | |
Electrical | ||
Electrical supply | 230V, 1Ph, 50Hz | |
Power consumption - maximum boiler modulation | W | 204 |
Start current (per module) | Amp | 3.5 |
Run current (per module) | Amp | 0.89 |
Approx shipping weight | kg | 340 |
Noise emission @1m: @max. modulation | dB (A) | 65 |
*390kW, 450kW, 525kW and 600kW models Nat Gas only | ||
**(0% excess oxygen, mg/kWh dry air free); NG/LPG |
Downloads
Varmax boiler brochureProduct brochures 5806 kb |
Download | |
500001305-B QAA73.210 Programmable Room Unit Guide.pdfInstallers guides 1783 kb |
Download | |
AGU 2.550 Kit instructionsInstallers guides 445 kb |
Download | |
Navistem B3000 controller instruction manualInstallers guides 2177 kb |
Download | |
QAA55 room unit programming instructionsInstallers guides 153 kb |
Download | |
QAA74 - Technical ManualInstallers guides 1640 kb |
Download | |
QAA74 Quick Reference GuideInstallers guides 178 kb |
Download | |
Siemens room operator units QAA55, QAA75, QAA78, AVS13, AVS14, AVS71Installers guides 6621 kb |
Download | |
Varmax Boiler installation manualInstallers guides 11421 kb |
Download | |
Varmax accessory AVS75 installation manualInstallers guides 2767 kb |
Download | |
Volt Free Contact (VFC) and switch fitting instructionsInstallers guides 1349 kb |
Download |
Ideal uses/applications
- Split temperature systems such as a combination of radiator loops/air convectors and underfloor heating.
- Medium to large sized district heating schemes.
- Schools.
- Shopping centres.
- Offices.
- Sports facilities.
- Health facilities.
Optional extras
- A large range of off the shelf flue options available
- Room sealed and open flue solutions
- Flue header kits
Single Boiler Controls
- Outside air temperature sensor QAC34 (Part no. 533901457)
- Domestic Hot Water sensor kit (sensor and pocket) QAZ36 (Part no. 563605674)
- Mixing valve heating circuit control kit (AVS 75 control module, temperature sensor and pocket) for 1 zone (Part no. 059751)
- Programmable room sensor QAA75 (Part no. 533901587)
- Offset adjustable room sensor QAA55 (Part no. 533901589)
Multiple Boiler Controls
- Outside air temperature sensor QAC34 (Part no. 533901457)
- Heating circuit sensor kit (sensor and pocket) QAZ36 (Part no. 563605673)
- Merley boiler sequence controller, wall mounted (Part no. 563605672)
- LPB Bus communication module OCI345, one required per boiler module (Part no. 563605667)
- Programmable room sensor QAA75 (Part no. 533901587)
- Offset adjustable room sensor QAA55 (Part no. 533901589)
- Choose from a wide range of service contracts to help maintain optimum performance.
- Book commissioning at the same time as placing your order for improved warranty terms.